Diagonal beam reinforcing for ductile frames
DOI:
https://doi.org/10.5459/bnzsee.12.4.346-356Abstract
This paper describes a system of diagonal beam reinforcing for reinforced concrete ductile frame buildings in seismic areas.
The development and application of the system is described with reference to the design of an 18 storey building.
The proposed reinforcing system has a number of major structural advantages over conventional reinforcing. Moments and shears within the beam span can be resisted entirely by the main reinforcing. Plastic hinge lengths are substantially increased and the hinging is kept away from the column face allowing concrete strut action to be effective in resisting forces within the elastic beam column joint.
References
T. Paulay. Moment Resisting Reinforced Concrete Frames - Shear Strength Requirements". Bulletin of the New Zealand National Society for Earthquake Engineering. Vol. 10, No. 2, June 1977.
R.A.Poole. "Design of a 28 Storey Reinforced Concrete Building in Wellington". Paper presented at South Pacific Regional Conference on Earthquake Engineering, May 1976.
T. Paulay, R. Park, M.J.N. Priestley. "Reinforced Concrete Beam Column Joints Under Seismic Actions". ACI Journal,Vol. 75, No. 11, November 1978. DOI: https://doi.org/10.14359/10971
R. Park and T. Paulay. Reinforced Concrete Structures John Wiley & Sons, 1975. DOI: https://doi.org/10.1002/9780470172834
R.W.G. Blakeley. "Seismic Design of Ductile Moment Resisting Reinforced Concrete Frames - Design of Beam Column Joints". Bulletin of the New Zealand National Society for Earthquake Engineering. Vo.10, No.4, December 1977.
T.PaulayandD.D.Spurr. "Frame-Shear Wall Assemblies Subjected to Simulated Seismic Loading". Proceedings of Sixth World Conference on Earthquake Engineering, New Delhi, January 1977.
I.N.Bull. "The Shear Strength of Relocated Plastic Hinges". Department of Civil Engineering Research Report No. 78/11. University of Canterbury. February 1978.
G.R.Birss. "The Elastic Behaviour of Earthquake Resistant Reinforced Concrete Interior Beam-Column Joints". Department of Civil Engineering Research Report No. 78-13. University of Canterbury. February 1978.
N.Z.N.S.E.E. Discussion Group. "Seismic Design of Ductile Moment Resisting Reinforced Concrete Frames". Bulletin of the New Zealand National Society for Earthquake Engineering. Vol.10, No.2, Vol.10, No. 4 and Vol. 11 No. 2.
T.Paulay. "Seismic Design of Ductile Moment Resisting Reinforced Concrete Frames - Columns: Evaluation of Actions". Bulletin of the New Zealand National Society for Earthquake Engineering. Vo.10,No.2. June 1977.
R. Park. "Seismic Design of Ductile Moment Resisting Reinforced Concrete Frames - Columns Subjected to Flexure and Axial Load". Bulletin of the New Zealand National Society for Earthquake Engineering. Vol.10,No.2. June 1977.