Cyclic load testing of two refined reinforced concrete beam-column joints

Authors

  • R. W. G. Blakeley Ministry of Works and Development, Wellington, New Zealand
  • F. D. Edmonds Ministry of Works and Development, Wellington, New Zealand
  • L. M. Megget Victoria University of Wellington, Wellington, NZ
  • J. H. Wood Ministry of Works and Development, Wellington, New Zealand

DOI:

https://doi.org/10.5459/bnzsee.12.3.238-255

Abstract

The paper describes the testing of two reinforced concrete beam-column joint units tested under incremented-static cyclic
 loading. The full size test units were based upon an interior beam-column joint of a four-storey 
framed building designed to the current NZ loading code and represent 
refinements on two previously tested conventional joints of similar dimensions. One unit differed from common practice by having a post-tensioned beam stressed to balance the floor dead load of the prototype structure whilst the second unit was detailed with haunched beams.

Hinge formation occurred in the beams and stable hysteretic behaviour was obtained up to displacement ductilities of 10 for the prestressed unit and 6 for the haunched unit. The test results are analysed in terms of the draft NZ design code, DZ 3101, and the ACI Recommendations for beam-column joint design.

References

New Zealand Standard for General Structural Design and Design Loading for Buildings, NZS 4203:1976, Part 3, 'Earthquake Provisions', Standards Association of New Zealand, Wellington, 1976.

Draft New Zealand Standard Code of Practice for the Design of Concrete Structures, DZ 3101, Standards Association of New Zealand, Wellington, 1978.

ACI-ASCE Committee 352, Recommendations for Design of Beam-Column Joints in Monolithic Reinforced Concrete Structures. ACI Journal, July 1976, pp. 375-393.

Blakeley, R.W.G., Megget, L. M. and Priestley, M. J. N., "Seismic Performance of Two Full-Size Reinforced Concrete Beam-Column Joint Units", Bull. N.Z. National Society for Earthquake Engineering, Vol. 6, No. 1, March 1975, pp. 38-69. DOI: https://doi.org/10.5459/bnzsee.8.1.38-69

Fenwick, R. C. and Irvine , H. M., "Reinforced Concrete Beam-Column Joints for Seismic Loading", Bull. N.Z. National Society for Earthquake Engineering, Vol. 10, No. 4, Dec. 1977, pp. 174-185. DOI: https://doi.org/10.5459/bnzsee.10.4.174-185

Park, R. and Thompson, K. J., "Some Recent Research in New Zealand into Aspects of the Seismic Resistance of Prestressed Concrete Frames", Bull. N.Z. National Society for Earthquake Engineering, Vol. 9, No. 3, Sept. 1976 , pp. 167-174.

Park, R., "Earthquakes and Structural Concrete", New Zealand Engineering, Vol. 34, No. 1, Jan. 1979 , pp. 2-10.

Bertero, V. V. and Popov, E. P., "Hysteretic Behaviour of Ductile Moment Resisting Reinforced Concrete Frame Components", Earthquake Engineering Research Centre, Report No. 75-16, University of California, Berkeley, April 1975.

Blakeley, R. W. G., "Design of Beam-Column Joints", Bull. N.Z. National Society for Earthquake Engineering, Vol. 10, No. 4, Dec. 1977, pp. 226-237. DOI: https://doi.org/10.5459/bnzsee.10.4.226-237