Supplemental dampers in base-isolated buildings to mitigate large isolator displacement under earthquake excitations

Authors

  • Daniel H. Zelleke Indian Institute of Technology (IIT) Delhi, New Delhi, India
  • Said Elias Indian Institute of Technology (IIT) Delhi, New Delhi, India https://orcid.org/0000-0002-8231-9765
  • Vasant A. Matsagar Indian Institute of Technology (IIT) Delhi, New Delhi, India
  • Arvind K. Jain Indian Institute of Technology (IIT) Delhi, New Delhi, India

DOI:

https://doi.org/10.5459/bnzsee.48.2.100-117

Abstract

The effect of viscous, viscoelastic, and friction supplemental dampers on the seismic response of base-isolated building supported by various isolation systems is investigated. Although base-isolated buildings have an advantage in reducing damage to the superstructure, the displacement at the isolation level is large, especially under near-fault ground motions. The influence of supplemental dampers in controlling the isolator displacement and other responses of base-isolated building is investigated using a multi-storey building frame. The coupled equations of motion are derived, solved and time history analysis is carried out on a building modeled with fifteen combinations of five isolation systems and three passive dampers. The seismic responses are compared with that of the fixed-base and base-isolated buildings. Based on the results, it is concluded that supplemental dampers are beneficial to control the large deformation at the isolator level. Parametric study is conducted and optimum ranges of damper parameters to achieve reduced isolator displacement without adverse effect on the other responses are determined. Further, it is concluded that the combination of the resilient-friction base isolator (R-FBI) and viscous damper is the most effective in reducing the bearing displacement without significant increase in superstructure forces.

References

Kelly JM (1986). “Aseismic Base Isolation: Review and Bibliography”. Soil Dynamics and Earthquake Engineering, 5(3): 202-216. DOI: https://doi.org/10.1016/0267-7261(86)90006-0

Jangid RS and Datta TK (1995). “Seismic Behavior of Base-Isolated Building: A State-of-the-Art Review”. Structures and Buildings, 110(2): 186-203.

Kelly JM and Hodder SB (1982). “Experimental Study of Lead and Elastomeric Dampers for Base Isolation Systems in Laminated Neoprene Bearings”. Bulletin of the New Zealand National Society for Earthquake Engineering, 15(2): 53-67.

Shimoda I, Nakano S, Kitagawa Y and Miyazaki M (1988). “Experimental Study on Base-Isolated Building using Lead Rubber Bearing through Vibration Tests”. Ninth World Conference on Earthquake Engineering, Tokyo-Kyoto, Japan, 2 August - 9 August 1988, Volume 5, 711-716.

Mokha A, Constantinou MC, Reinhorn AM and Zayas VA (1991). “Experimental Study of Friction-Pendulum Isolation System”. Journal of Structural Engineering, 117(4): 1201-1217. DOI: https://doi.org/10.1061/(ASCE)0733-9445(1991)117:4(1201)

Rao PB and Jangid RS (2001). “Experimental Study of Base-Isolated Structures”. ISET Journal of Earthquake Technology, 38(1): 1-15.

Fenz DM and Constantinou MC (2006). “Behaviour of the Double Concave Friction Pendulum Bearing”. Earthquake Engineering and Structural Dynamics, 35: 1403-1424.

Rabiei M and Khoshnoudian F (2011). “Response of Multistory Friction Pendulum Base-Isolated Buildings Including the Vertical Component of Earthquakes”. Canadian Journal of Civil Engineering, 38: 1045-1059.

Nanda RP, Agarwal P and Shrikhande M (2012). “Suitable Friction Sliding Materials for Base Isolation of Masonry Buildings”. Shock and Vibration, 19: 1327-1339.

Ponze FC, Cesare AD, Nigro D, Simonetti M and Leccese G (2014). “Shaking Table Tests of a Base Isolated Structure with Double Concave Friction Pendulums”. Proceedings of the 2014 NZSEE Conference, Auckland, New Zealand, 21 March - 23 March 2014, Paper No 43.

Hall JF, Heaton TH, Halling MW and Wald DJ (1995). “Near-Source Ground Motion and Its Effects on Flexible Buildings”. Earthquake Spectra, 11(4): 569-605. DOI: https://doi.org/10.1193/1.1585828

Jangid RS and Kelly JM (2001). “Base Isolation for Near-Fault Motions”. Earthquake Engineering and Structural Dynamics, 30: 691-707.

Kelly JM (1999). “The Role of Damping in Seismic Isolation”. Earthquake Engineering and Structural Dynamics, 28(1): 3-20. DOI: https://doi.org/10.1002/(SICI)1096-9845(199901)28:1<3::AID-EQE801>3.0.CO;2-D

Jangid RS (2005). “Optimum Friction Pendulum System for Near-Fault Motions”. Engineering Structures, 27: 349-359.

Jangid RS (2007). “Optimum Lead-Rubber Isolation Bearings for Near-Fault Motions”. Engineering Structures, 29: 2503-2513.

Makris N and Chang SP (1998). “Effect of Viscous, Viscoplastic and Friction Damping on the Response of Seismic Isolated Structures”. ISET Journal of Earthquake Technology, 35(4): 113-141.

Zhang Y and Iwan WD (2002). “Protecting Base-Isolated Structures from Near-Field Ground Motion by Tuned Interaction Damper”. Journal of Engineering Mechanics, 128: 287-295.

Lu LY and Lin GL (2009). “Improvement of Near-Fault Seismic Isolation using a Resettable Variable Stiffness Damper”. Engineering Structures, 31: 2097-2114.

Ozbulut OE, Bitaraf M and Hurlebaus S (2011). “Adaptive Control of Base-Isolated Structures against Near-Field Earthquakes using Variable Friction Dampers”. Engineering Structures, 33: 3143-3154.

Chang SP, Makris N, Whittaker AS and Thompson AC (2002). “Experimental and Analytical Studies on the Performance of Hybrid Isolation Systems”. Earthquake Engineering and Structural Dynamics, 31: 421-443.

Kim HS, Roschke PN, Lin PY and Loh CH (2006). “Neuro-Fuzzy Model of Hybrid Semi-Active Base Isolation System with FPS Bearings and an MR Damper”. Engineering Structures, 28: 947-958.

Lu LY and Lin GL (2008). “Predictive Control of Smart Isolation System for Precision Equipment Subjected to Near-Fault Earthquakes”. Engineering Structures, 30: 3045-3064.

Providakis CP (2008). “Effect of LRB Isolators and Supplemental Viscous Dampers on Seismic Isolated Buildings under Near-Fault Excitations”. Engineering Structures, 30: 1187-1198.

Lu LY, Lin CC and Lin GL (2013). “Experimental Evaluation of Supplemental Viscous Damping for Sliding Isolation System under Pulse-Like Base Excitations”. Journal of Sound and Vibration, 332: 1982-1999.

Oh SH, Song SH, Lee SH and Kim HJ (2013). “Experimental Study of Seismic Performance of Base-Isolated Frames with U-Shaped Hysteretic Energy-Dissipating Devices”. Engineering Structures, 56: 2014-2027.

Qin C, Liu W, and He W (2014). “Seismic Response Analysis of Isolated Nuclear Power Plants with Friction Damper Isolation”. 2nd AASRI Conference on Power and Energy Systems, Jeju Island, Korea, 27 December - 28 December 2013, Volume 7, Paper No 5, 26-31. DOI: https://doi.org/10.1016/j.aasri.2014.05.024

Wen, YK (1976). “Method for Random Vibrations of Hysteretic Systems”. Journal of Engineering Mechanics Division, 102: 249-263.

Zayas VA, Low SS and Mahin SA (1990). “A Simple Pendulum Technique for Achieving Seismic Isolation”. Earthquake Spectra, 6(2): 317-333. DOI: https://doi.org/10.1193/1.1585573

Mostaghel N and Khodaverdian M (1987). “Dynamics of Resilient-Friction Base Isolator (R-FBI)”. Earthquake Engineering and Structural Dynamics, 15: 379-390.

Matsagar V, Jangid RS (2006). “Base-Isolated Building Connected to Adjacent Building using Viscous Dampers”. Bulletin of the New Zealand Society for Earthquake Engineering, 39(1): 59-80. DOI: https://doi.org/10.5459/bnzsee.39.1.59-80

Downloads

Published

30-06-2015

How to Cite

Zelleke, D. H., Elias, S., Matsagar, V. A., & Jain, A. K. (2015). Supplemental dampers in base-isolated buildings to mitigate large isolator displacement under earthquake excitations. Bulletin of the New Zealand Society for Earthquake Engineering, 48(2), 100–117. https://doi.org/10.5459/bnzsee.48.2.100-117

Issue

Section

Articles

Categories