Response of seismically isolated buildings with buffers subjected to near-source ground motions and possible alternative isolation systems
DOI:
https://doi.org/10.5459/bnzsee.37.3.111-133Abstract
The response of a seismically isolated building with lead rubber bearings (LRB) to near source ground motions from large earthquakes was investigated. The building was assumed to have a buffer to limit the maximum bearing displacement in a rare event of large magnitude and the buffer gap was assumed to be only 150mm (the level of maximum isolator displacement used in the 1980s). The structure was assumed to be designed for 1.5 times the NS component of the 1940 El Centro record. The 15% damped (an amount of damping which is close to the equivalent damping ratio for an seismically isolated building at its isolator design displacement) displacement spectrum of the design motion is only 40% that of the Sylmar County Hospital Parking Lot record from the 1994 Northridge earthquake (Mw= 6.7) in the period range around the first modal periods of both isolated and un-isolated structure used in the present study. Among the near-source records that are available, the near-source Sylmar record from the 1994 Northridge earthquake was found to have a very large displacement demand in a period range of 2.0 - 3.0s and this record is thought to be a better representation of the expected near-source motions than the 1.5 times the 1940 El Centro record.
Structure-buffer impact was found to impose very large inter-storey drifts and produce very large storey accelerations, when the building was subjected to the excitation of the Sylmar record. The structure-buffer impact was found to be detrimental to the structural response if the structure was not designed to provide inelastic deformation capacity, and the structural response did not improve when the gap was increased to 200-250 mm, the expected maximum displacement capacity of the LRBs used in the building. An alternative isolation system of LRBs and hysteretic dampers was investigated and found to be adequate for resisting near-source motions. A large initial damper stiffness and relatively small buffer stiffness (compared with the total initial stiffness of LRBs) were found to be effective in reducing inter-storey drifts and storey accelerations at floors except for the base and roof of the structure. A disadvantage of such a system is the relatively large base and roof accelerations. The system has relatively large inter-storey drifts and storey accelerations compared with an isolated structure using LRBs only when the structure was subjected to either the 1940 El Centro type ground motions or the Joshua Tree type ground motions with backward directivity effect. Such an isolation system would still enable the structure to respond essentially elastically under the excitation of the Sylmar record even though the isolated structure was designed for a much lower level of ground shaking.
As the upper structure of a seismically isolated building is usually designed to respond essentially elastically, the detailing used in the design of a reinforced concrete structure to provide inelastic deformation capacity was generally uncommon and was not fully accounted for in the present study.
References
Robinson, W.H. (1982), "Lead-rubber hysteretic bearings suitable for protecting structures during earthquakes", Earthquake Engineering and Structural Dynamics, 10:593-604. DOI: https://doi.org/10.1002/eqe.4290100408
Megget, L.M. (1978), "Analysis and design of a base-isolated reinforced concrete frame building", Bulletin of the New Zealand National Society for Earthquake Engineering, 11(4):245-254.
Charleson, A.W., Wright, P.D. and Skinner, I.R. (1987), "Wellington Central Police Station: base isolation of an essential facility", Pacific Conference on Earthquake Engineering, NZNSEE, New Zealand, 2:377-388
Robinson, W.H. and Greenbank, L.R. (1976), "An extrusion energy absorber suitable for the protection of structures during an eat1hquake", Earthquake Engineering and Structural Dynamics, 4:251-259. DOI: https://doi.org/10.1002/eqe.4290040306
Dowrick, D.J., Babor, J., Cousins, W.J. and Skinner, R.I. (1991), "Design of a seismically isolated printing press", Pacific Conference on Earthquake Engineering, NZNSEE, New Zealand, 3:35-44.
Somerville, P.O., Smith, N.F., Graves, R.W. and Abrahamson, N.A. (1997), "Modification of empirical strong ground attenuation relations to include the amplitude and duration effects of rupture directivity", Seismological Research Letters, 68(1): 199-222. DOI: https://doi.org/10.1785/gssrl.68.1.199
Hall, J.F., Heaton, T.H., Halling, M.W. and Wald, D.J., (1995), "Near-source ground motion and its effects on flexible buildings", Earthquake Spectra, 11(4):569-606. DOI: https://doi.org/10.1193/1.1585828
Makris, N. (1997), "Rigidity-plasticity-viscosity: can electrorheological dampers protect base-isolated structures from near-source ground motions?" Earthquake Engineering and Structural Dynamics, 26(5):571-591. DOI: https://doi.org/10.1002/(SICI)1096-9845(199705)26:5<571::AID-EQE658>3.0.CO;2-6
Tsai, H.-C. (1997), "Dynamic analysis of base-isolated shear beams bumping against stops", Earthquake Engineering and Structural Dynamics, 26(5):515-528. DOI: https://doi.org/10.1002/(SICI)1096-9845(199705)26:5<515::AID-EQE654>3.0.CO;2-C
Davidson, B.J., Megget, L.M. and Chan, W. (1998), "The reanalysis of the base isolated William Clayton building to near source earthquakes", Proceedings of NZNSEE Annual Conference, Wairakei, March 1998, 197-203.
Skinner, R.I., Robinson, W.H. and McYetTy, G.H. (1993), An introduction to seismic isolation (3 versions in English, Japanese and Chinese respectively), John Wiley and Sons Ltd., West Sussex, England.
Maison. B.F. (1992), "PC-ANSR, A general purpose computer program for nonlinear static and dynamic analysis of three dimensional finite element structural systems".
Paulay, T. and Priestley, M.J.N. (1992), Seismic design of reinforced concrete and masonry buildings, John Wiley & Sons, Inc. DOI: https://doi.org/10.1002/9780470172841
International Conference of Building Officials 1997, "Earthquake regulations for seismic-isolated structures", Uniform Building Code, Appendix Chapter 16, Whittier, CA.
Bernal D. (1994), "Viscous Damping in Inelastic Structural Response", Journal of Structural Engineering. American Society of Civil Engineers, 120(4): 1240-1254. DOI: https://doi.org/10.1061/(ASCE)0733-9445(1994)120:4(1240)
Zhao. J.X., Dowrick, DJ., and McVeny, G.H. (1997), "Attenuation of peak ground accelerations in New Zealand earthquakes", Bulletin of the New Zealand National Society for Earthquake Engineering, 30:133-158. DOI: https://doi.org/10.5459/bnzsee.30.2.133-158
Tyler, R.G. (1991), "Rubber bearings in bease-isolated structures - a summary paper", Bulletin of the New Zealand National Society for Earthquake Engineering, 24(3):251-274. DOI: https://doi.org/10.5459/bnzsee.24.3.251-274
Monti, M.D., Zhao, J.X., Gannon, C.R. and Robinson, W.H., (1998), "Experimental results and dynamic parameters for the Penguin Vibration Damper (PVD) for wind and earthquake loading", Bulletin of the New Zealand National Society for Earthquake Engineering, 31(1): 177-193 DOI: https://doi.org/10.5459/bnzsee.31.3.177-193
Boardman, P.R. and Kelly, T.E. (1993), "Seismic design of the museum of New Zealand, Te Papa Tongarewa", Proceedings of NZNSEE Annual Conference, Wairakei, March 1993, 80-87.
Hall, J.F. (editor, 1995), "Recorded ground and structure motions", Earthquake Spectra, 11(1): 13-96. DOI: https://doi.org/10.1193/1.1585846