Understanding the complexities of designing diaphragms in buildings for earthquakes
DOI:
https://doi.org/10.5459/bnzsee.37.2.70-88Abstract
The variety of layouts of lateral force resisting elements in structures, subjected to inelastic behaviour, make the design of diaphragms significantly more complex than the traditional "simple beam" approach typically employed.
Traditionally held views that diaphragms are inherently robustness and hence do not require significant engineering input have been shown to be inappropriate by recent major earthquakes and recent laboratory studies.
The simple beam method, at times, fails to recognise that the traditional load paths assumed are compromised by localised damage in the floors (diaphragms) due to incompatibility of deformation between the floors and the supporting structures (walls, beam and columns). "Strut and tie" methods are suggested as a means of tying these diaphragms into the lateral force resisting structures and as a way of dealing irregular floor plates and penetrations (stairs, lifts, atriums) through the floors.
The focus of recent research in determining the seismic lateral forces into and through floor diaphragms has been on the magnitude of the floor inertias. However, it has been shown that primary structural elements interacting through the diaphragm, can cause stresses in the floors many more times than those of the inertia effects. These two sources of forces and stresses are interrelated. This relationship requires further study.
Survivability of a building rests, in part, on the diaphragms tying the structure together. Suggestions for maintaining the integrity of the diaphragms, particularly in precast concrete types, are discussed.
References
British Standards Institute (1985). "BS 8110: Parts 1 and 2, 1985 Structural Use of Concrete", BSI, United Kingdom, Milton Keynes.
Bull, D.K. (1997). ·"'Diaphragms", Seismic Design of Reinforced Concrete Structures", Technical Report No. 20, New Zealand Concrete Society.
CAE (2nd ed.) (1999). "Guidelines for the Use of Structural Precast Concrete in Buildings", Report of the Study Group of the New Zealand Concrete Society and the New Zealand National Society for Earthquake Engineering. Christchurch, Centre of Advanced Engineering, CAE, University of Canterbury.
Fenwick, R.C. and Mcgget, L.M. (1993). "Elongation and Load Deflection Characteristics of Reinforced Concrete Members Containing Plastic Hinges", Bulletin of the New Zealand National Society for Earthquake Engineering, Vol. 26 (1), 28-41.
Fleischman, R. B., Fan-ow, K. T. and Eastman, K. (2001). "Seismic Response of Perimeter Lateral-System Structures with Highly Flexible Diaphragms", Earthquake Spectra, Vol. 18 (3).
Goodsir, W.J. (1985). "The Design of Frame-Wall Structures for Seismic Actions". Research Report No. 85-8, Department of Civil Engineering, University of Canterbury, Christchurch.
Herlihy, M.D., Park, R. and Bull, D.K. (1996). "Interaction between Dissimilar Structural Elements: the Need to Reconsider Capacity Design Principles for Reinforced Concrete Diaphragms Subjected to Seismic Actions", Proceedings of the Technical Conference of the New Zealand National Society for Earthquake Engineering, NZSEE, Wairakei, March 1996, pp. 12-19.
Iverson, J.K. and Hawkins, N.M. (1994). "Performance of Precast/Prestressed Concrete Bridges during the Northridge Earthquake", Journal of the Prestressed Concrete Institute, Vol. 39 (2) 38-55.
Lau, D.B.N. (2001). "The influence of Precast-Prestressed Flooring on the Seismic Performance of Reinforced Concrete Perimeter Frame Buildings", Report No. 604. Department of Civil and Resource Engineering, University of Auckland, Auckland.
McSaveney, L.G. (1997). "Precast Concrete Flooring Systems - Design and Detailing for Seismic Purposes", New Zealand Concrete Society Conference Technical Papers (TR 19), Wairakei, p 14-26, New Zealand Concrete Society.
Matthews, J., Bull, D. K. and Mander, J. (2003a). "Background to the testing of a precast concrete hollowcore floor slab building", Proceedings, 2003 Pacific Conference on Earthquake Engineering, paper 170, Christchurch, NZSEE.
Matthews, J., Bull, D. K. and Mander, J. (2003b). "Preliminary results from the testing of a precast hollowcore floor slab building", Proceedings, 2003 Pacific Conference on Earthquake Engineering, paper 077, Christchurch, NZSEE.
Nakaki, S. D. (2000). "Design Guidelines for Precast and Cast-in-Place Concrete Diaphragms", Technical Report, EERI Professional Fellowship, April 2000: Earthquake Engineering Research Institute.
NZCS (1994). "Revisions to the New Zealand Standard for the Design of Concrete Structures: NZS 3101", Technical Report No. 15 (TR15), May 1994, New Zealand Concrete Society.
Oliver, S., Bull, D. K. and Restrepo, J. (1998). "The Performance of Concrete Topped Concrete Hollowcore flooring systems reinforced with and without Dramix Steel Fibres Under Simulated Seismic Loading", Proceedings, Australasian Structural Engineering Conference, Auckland, 1998. Vol. 1 pp 325-332. Auckland, ASEC.
Park, R. and Gamble, W. (2nd ed.) (2000). Reinforced Concrete Slabs. John Wiley & Sons, New York.
Paulay, T. (1996). "Seismic Design of Concrete Structures - Present Needs of Societies". Proceedings 11th World Conference on Earthquake Engineering, Acapulco, Mexico, June 1996. Paper No. 2001.
Paulay, T. and Priestley, M.J.N. (1992). Seismic Design of Reinforced Concrete and Masonry Buildings, John Wiley and Sons, New York. DOI: https://doi.org/10.1002/9780470172841
Rodriguez, M.E., Restrepo, J.I. and Carr, A.J. (2002). "Earthquake Induced Floor Horizontal Accelerations in Buildings", Earthquake Engineering and Structural Dynamics. DOI: https://doi.org/10.1002/eqe.149
Stewart, N.L. (1995). "An analytical study of the seismic response of reinforced concrete frame-shear wall structures", Master of Engineering Report, Department of Civil Engineering, University of Canterbury.
SANZ (1992). "General Structural Design and Design Loadings for Buildings, NZS 4203: 1992", Wellington, Standards New Zealand.
SANZ (1995). "Concrete Structures Standard - The Design of Concrete Structures NZS 3101: Part 1: 1995 and Commentary on the Design of Concrete Structures NZS 3101: Part 2:1995", and "Amendment No. 1 to NZS 3101 Parts 1 and 2, 1995", Wellington, Standards New Zealand.
Schlaich, J., Schaefer, K. and Jennewcin, M. (1987). "Towards a Consistent Design of Structural Concrete", Journal of the Prestressed Concrete institute, Chicago 11., Vol. 32 (3) 74-150. DOI: https://doi.org/10.15554/pcij.05011987.74.150