Seismic design of glulam structures

Authors

  • A. H. Buchanan University of Canterbury, Christchurch, New Zealand
  • R. H. Fairweather Works Consultancy Services Ltd, Greymouth, New Zealand

DOI:

https://doi.org/10.5459/bnzsee.26.4.415-436

Abstract

This paper gives an overview of the seismic performance of glue laminated (glulam) timber frame buildings. It describes the wide range of connections that can be used in glulam frames, for both single storey and multi-storey buildings, with particular reference to seismic loading.

Several new connections incorporating epoxied steel bars are described in detail. Testing of these connections under simulated seismic loading is reported, with recommendations for seismic design.

A design procedure is given for low rise multi-storey glulam frame buildings.

References

Thomas, G.C., 1991. "The Feasibility of Multistorey Light Timber Frame Buildings", Research Report 91-2, Department of Civil Engineering, University of Canterbury.

Halliday, M . A L 1991. "Feasibility of Medium Rise Timber Office Buildings", Research Report 91-3, Department of Civil Engineering, University of Canterbury.

Touliatos, P.G., 1991. "Design Problems of the Timber Framed Construction in Seismic Zones", Proceedings of the 1991 International Timber Engineering Conference, London, United Kingdom, Volume 4, pp. 275-282.

Batchelar, M.L. and Hunt, R.D., 1991. "Composite Plywood and Steel Gusset Plates for Moment-Resisting Joints in Timber Frames", Proceedings of the 1991 International Conference on Timber Engineering, London, United Kingdom, Volume 3, pp. 104-110.

Walford, C.B. 1989. "Portal Frames" Section B-2 of Timber Use Manual. New Zealand Timber Industry Federation, Wellington.

Hunt, R.D. and Bryant, A.H., 1988. "Moment-Resisting Nail Plate Joints - Recent Developments at Auckland University", Proceedings of the 1988 International Conference on Timber Engineering, Seattle, USA, Volume 1, pp.251-256.

Buchanan, A.H. and Dean, J.A. 1988. "Practical Design of Timber Structures to Resist Earthquakes", Proceedings of the 1988 International Conference on Timber Engineering, Seattle, USA, Volume 1, pp. 813-822.

Ceccotti, A. and Vignoli, A., 1988. 'The Effects of Seismic Events on the Behaviour of Semi-Rigid Joint Timber Structures - A Simulation of the Influence of Structural Scheme and of Joint Characteristic", Proceedings of the 1988 International Timber Engineering Conference, Seattle, USA, Volume 1, pp. 823-837.

Komatsu, K., Kawamoto, N., Kazumi, H. and Harada, M., 1991. "Modified Glulam Moment-Resisting Joints", Proceedings of the 1991 International Conference on Timber Engineering, London, United Kingdom, Volume 3, pp. 111-118.

McIntosh, K.A., 1989. "From Theory to Reality - 30 years in Glulam Manufacture", Proceedings of the Second Pacific Timber Engineering Conference, Auckland, New Zealand.

Riberholt, H., 1986. "Glued Bolts in Glulam", Department of Structural Engineering, Technical University of Denmark, Series R, Number 210.

Buchanan, A.H. and Fletcher, M.R. 1989. "Glulam Portal Frame Swimming Pool Construction", Proceedings of the Second Pacific Timber Engineering Conference, Auckland, New Zealand, 1989, Volume 1, pp.245-249.

Townsend, P.K., 1990. "Steel Dowels Epoxy Bonded in Glulam Timber", Research Report 90-11, Department of Civil Engineering, University of Canterbury.

Buchanan, A.H., Moss, P.J. and Townsend, P.K. 1990. "Reinforced Bars Epoxy Bonded in Glue Laminated Timber", Proceedings of the 1990 International Conference on Timber Engineering, Tokyo, Japan, Volume 2, pp.601-610.

Buchanan, A.H. and Townsend, P.K., 1990. "Portal Frame Knee Joints with Epoxied Steel Dowels", Report to Hunter Laminates Ltd, Canterprise, University of Canterbury.

Gardner, G.P., 1991. "A Reinforced Glued Laminated Timber System", Proceedings of the 1991 International Conference on Timber Engineering, London, United Kingdom, Volume 3, pp 3.218-3.225.

Tukovsky, S.B., 1991. "Use of Glued-In bars for Reinforcement of Wood Structures", Proceedings of the 1991 International Timber Engineering Conference, London, United Kingdom, Volume 3, pp. 143-148.

Fairweather, R.H. 1992. "Beam Column Connections for Multi-storey Timber Buildings". Research Report 92-5 Department of Civil Engineering, University of Canterbury.

Buchanan, A.H. and Fairweather, R.H. 1992. Design Guide for Glulam Portal Frames with Steel Knee Joints. Report to Hunter Laminates Ltd, Canterprise, University of Canterbury.

SANZ 1992. NZS 4203:1992 "General Structural Design and Design Loadings for Buildings", Standards Association of New Zealand, Wellington.