The ductility of structural walls
DOI:
https://doi.org/10.5459/bnzsee.18.3.250-269Abstract
The behaviour of four approximately 1/4 full size reinforced concrete structural wall models, subjected to cyclic lateral shear load and variable axial compression, is reported. The primary aim of the study was to investigate the mechanism of out of plane instability and the adequacy of existing code provisions with respect to the confinement of critical parts of the flexural compression zones of wall sections that may be subjected during an earthquake to large inelastic displacements. While all units exhibited good energy dissipation properties, failure in the majority of cases occurred suddenly when concrete compression strains resulting from large ductility demands became excessive in the unconfined regions of the wall section. Failure by out of plane buckling was found to occur at a relatively small lateral load, after the buckled region has been subjected in a proceeding cycle to very large inelastic tensile strains. Recommendations are made for improved arrangement of the confining hoop reinforcement in the end regions of wall sections.
References
SEAOC, "Recommended Lateral Force Requirements and Commentary", Seismology Committee, Structural Engineers' Association of California, San Francisco, 1973, 146pp.
Oesterle, R.G., et al, "Earthquake Resistant Structural Walls - Tests of Isolated Walls Appendix B - Test Results", Portland Cement Association, Skokie, 1976, 233pp.
Oesterle, R.G., ET AL, "Earthquake Resistant Structural Walls - Tests of Isolated Walls, Phase II", Portland Cement Association, Skokie, 1979, 84pp. plus appendices.
Vallenas, J.M., Bertero, V.V. and Popov, E.P., "Hysteretic Behaviour of Reinforced Concrete Structural Walls", Report UBC/EERC 79/20, Earthquake Engineering Research Center, University of California, Berkeley, 1979, 234pp.
Spurr, D.D., "Post Elastic Behaviour of Reinforced Concrete Frame-Wall Components and Assemblages Subjected to Simulated Seismic Loading", Ph.D. Thesis, Department of Civil Engineering, University of Canterbury, New Zealand, 1984, 498pp.
Park, R. and Paulay, T., "Reinforced Concrete Structures", John Wiley and Sons, New York, 1975, 769pp. DOI: https://doi.org/10.1002/9780470172834
Paulay, T. and Williams, R.L., "The Analysis and Design of and the Evaluation of Design Actions for Reinforced Concrete Ductile Shear Wall Structures", Bulletin of the New Zealand National Society for Earthquake Engineering, Vol. 13, No. 2, June 1980, pp.108-143.
NZS 3101:1982, Parts 1 and 2, "Code of Practice for the Design of Concrete Structures", Standards Association of New Zealand, Wellington, 283pp.
NZS 4203:1976, "Code of Practice for General Structural Design and Design Loadings for Buildings", Standards Association of New Zealand, Wellington, 80pp.
Goodsir, W.J., "The Design of Coupled Frame-Wall Structures for Seismic Actions", Ph.D. Thesis, University of Canterbury, Christchurch, New Zealand, 1985, 385pp.
ACI Committee 318, "Building Code Requirements for Reinforced Concrete", (ACI 318-77), American Concrete Institute, Detroit, 1977, 102pp.
Park, R., Priestley, M.J.N, and Gill, W.G., "Ductility of Square Confined Concrete Columns", Journal of Structural Division, Proceedings of American Society of Civil Engineers, Vol. 108, No. ST4, April 1982, pp.929-950.
Mander, J.B., "Seismic Design of Bridge Piers", Research Report 84-2, Department of Civil Engineering, University of Canterbury, New Zealand, 1984, 442pp.