The seismic performance of energy absorbing dampers in building structures
DOI:
https://doi.org/10.5459/bnzsee.17.1.38-46Abstract
By separating the stiff shear walls of the structural core of a building from the more flexible column/beam/slab structure two independent structures with markedly different dynamic properties are formed. By introducing damping elements between the two, energy is absorbed during earthquakes, giving consider- ably improved response characteristics.
A ten storey office structure incorporating dampers in this fashion is studied by time history analysis, using five simulated earthquakes. Dampers are provided at each floor level. The analysis treats the damping as hysteretic, based on the type described by Kelly (1972).
Significant reductions in structural response are achieved by this means.
References
Anon, "Dampers blunt the wind! s force on tall buildings" Architectural Record, September 1971.
D.A. Gasparini, A.D. Chaudhury, L.W. Curry, "Damping of frames with constrained viscoelastic layers" Jnl of the Struct Div, ASCE, ST1, Jan 1980, 115-131.
J.M. Kelly, R.I. Skinner, A.J. Heine, "Mechanisms of energy absorption in special devices for use in earthquake resistant structures", Bull of N.Z. Soc for Earthquake Eng, V5, No 3, Sept. 1972.
K. Matsushita, M. Izumi, "Application of input controlling mechanisms to structural design of a tall building1, Proc. 5th World Conf. on Earthquake Eng, Rome 1973, V2, 2948-2955.
W.H. Robinson, L.R. Greenbank , “An extrusion energy absorber suitable for the protection of structures during an earthquake”) Earthquake Eng. & Struct. Dynamics, V4, 1976, 251-259. DOI: https://doi.org/10.1002/eqe.4290040306
R.I. Skinner, J.M. Kelly, A.J. Heine, "Hysteretic dampers for earthquake resistant structures”, Earthquake Eng. & Struct. Dynamics, V3 , 1975, 287-296. DOI: https://doi.org/10.1002/eqe.4290030307
R.I. Skinner, J.L. Beck, G.N. Bycroft, “A practical system for isolating structures from earthquake attack”. Earthquake Eng. & Struct. Dynamics, V3, 1975, 297-309. DOI: https://doi.org/10.1002/eqe.4290030308
E. Zeller, "Dynamic tests on an actual building mounted with a new damper system1, Proc 5th World Conf. on Earthquake Eng., V2, Rome 1973, 1517-1520.