Local buckling of universal beam flanges

Authors

  • S. J. Thurston Ministry of Works and Development, Wellington, New Zealand

DOI:

https://doi.org/10.5459/bnzsee.15.2.96

Abstract

To study fatigue of defective welds, beam-column joints were cyclically loaded at MWD Central Laboratories. However, local buckling occurred in the beam
flanges during the first few cycles at displacement ductilities 2.25-2.6. Despite the buckling, the peak resisted load had a maximum of 15% reduction after 10 cycles at these ductilities, and the hysteresis loops showed little change
in shape. Nevertheless, because steel frame structures can be expected to sustain a ductility demand of about 4/SM or 6, there is clearly some doubt as to whether the strength of a system already buckling at a DF < 3 would be maintained under
the design earthquake. The 310 UB 40 beam tested complied with the current NZ Steel Code, which required no stiffeners in this case.

References

NZS 3404:1977, New Zealand Standard "Code for Design of Steel Structures", SANZ, Wellington 1977.

Bresler and Lin, "Design of Steel Structures", Wiley p43.

ASCE Manual No. 41, "Plastic Design in Steel", ASCE 1971.

Shepherd, R., and Spring, K.E.C., "Racking Load Tests on a Steel Beam-Column Joint", NZ Engineering, Volume 30, 1975, pp 326-331.

Downloads

Published

30-06-1982

Issue

Section

Technical Notes

Categories

How to Cite

Thurston, S. J. (1982). Local buckling of universal beam flanges. Bulletin of the New Zealand Society for Earthquake Engineering, 15(2), 96. https://doi.org/10.5459/bnzsee.15.2.96