Background material to seismic design aspects of the draft masonry design code DZ4210 is presented. The design approach is based on specified lateral force levels appropriate to the available but limited ductility, and on the principles of reinforced concrete section analyses adapted for low material strengths. Ultimate masonry strengths for compression, shear and flexure are based on the construction techniques and extent of supervision rather than on the strengths of the masonry constituents. Design lateral force coefficients for flexural strength depend on the characteristics of the structural system adopted and Structural Type factors (S) are proposed that are more appropriate to masonry structures than current values incorporated in the Loadings Code NZS4203. Shear failure is proscribed by the implementation of capacity design principles, though simplified procedures are allowed for structures with high flexural S factors. Brief discussion is made of so-called non-structural masonry, including veneers, partition, infill and secondary walls.
References
'Design and Construction - Masonry', NZSS1900, Ch.9.2:1964, S.A.N.Z., Wellington, 32pp.
Priestley, M.J.N, and Bridgeman, D.O., ‘Seismic Resistance of Brick Masonry Walls', Bull. N.Z. National Society For Earthquake Engineering (NZNSEE), Vol. 7, No. 4, Dec. 1974, pp. 167-187.
Priestley, M.J.N., ‘Seismic Resistance of Reinforced Concrete Masonry Shear Walls', Bulletin NZNSEE, Vol. 10, No. 1, March 1977, pp 1-16.
Williams, D., 'Seismic Behaviour of Reinforced Masonry Shear Walls’, Ph.D. Thesis, University of Canterbury, New Zealand, 1971, 107p
Trounce, M.J. & Priestley, M.J.N., ‘Seismic Behaviour of Reinforced Concrete Masonry Shear Walls', Department of Civil Engineering, University of Canterbury Research Report 78-19, 112p.
Priestley, M.J.N., Thorby, P.N., McLarin, M.W. & Bridgeman, D.O., ‘Dynamic Performance of Brick Masonry Veneer Panels', Bulletin NZNSEE, Vol. 12, No. 4, December 1979, pp. 314-323.
'The Design of Masonry’, Draft Code DZ4210, Part B, 1980, S.A.N.Z., New Zealand.
N.Z. Standard Specification for Clay Building Bricks, NZSS366. 1963. S.A.N.Z., Wellington, 10pp.
Hamid, A.A. and Drysdale, R.G., 'Suggested Failure Criteria for Grouted Concrete Masonry Under Axial Compression', Journal ACI, V.76, No.10, Oct. 1979, pp.1047-1062. DOI: https://doi.org/10.14359/6973
Hilsdorf, H.K., 'An Investigation into the Failure Mechanism of Brick Masonry Under Axial Compression’, Designing, Engineering and Construction with Masonry Products, F.B. Johanson, Ed., Gulf Pub. Co., Houston, Texas, May 1969, pp. 34-41.
Skinner, R.I.,1 Earthquake Generated Forces and Moments in Tall Buildings', DSIR Bulletin 166, Wellington, 1964, 106pp.
Standards Association of New Zealand, 'General Structural Design and Design Loading for Buildings', NZS4203:1976, S.A.N.Z. Wellington, 1976, 81p.
Synge, T., Paulay, T. & Priestley, M.J.N., 'Ductility of Squat Shear Walls', Dept. of Civil Engineering, University of Canterbury Research Report No. 80-9, 1980.
'The Design of Concrete Structures', Draft Code DZ3101, S.A.N.Z., Wellington, 1980.
Mayes, R.L., Omoto, Y. & Clough, R.W., 'Cyclic Shear Tests of Masonry Piers', University of California Berkeley, Report EERC 76-8, May 1976, 84p.
Park, R. & Paulay, T., 'Reinforced Concrete Structures', John Wiley and Sons, New York, 1975, 769p. DOI: https://doi.org/10.1002/9780470172834
Rosenbleuth, E. (Ed), 'Earthquake Resistant Design of Structures', Ch. 7 - Masonry (M.J.N. Priestley), Pergamon Press, 1980pp.
Cardenas, A.E. et al, 'Design Provisions for Shear Walls', Jour. ACI, Vol. 70, No. 3, March 1973, pp. 221-230. DOI: https://doi.org/10.14359/11201
Priestley, M.J.N., & Elder, D.M., 'Seismic Behaviour of Slender Masonry Shear Walls', Department of Civil Engineering, University of Canterbury, Research Report (to be published).
Gill, W.D., Park, R., & Priestley, M.J.N., 'Ductility of Rectangular Reinforced Concrete Columns with Axial Load', Department of Civil Engineering, Res. Rep. 79-1, University of Canterbury, Feb. 1979, 136pp.
Ang, B.G., Priestley, M.J.N., and Park, R., 'Ductility of Slender Confined Concrete Columns1, Research Department, Department of Civil Engineering, University of Canter- bury, Feb. 1981 (to be published).
Blakeley, R.W.G., Cooney, R. & Megget, L.M., 'Seismic Shear Loading at Flexural Capacity in Cantilever Wall Structures', Bulletin NZNSEE, Vol. 8, No. 4, Dec. 1975, pp.278-290.
Schneider, R.R., 'Lateral Load Tests on Reinforced Grouted Masonry Shear Walls', University of Sth. California Engineering Centre Report 70-101, Sept. 1959.
Scrivener, J.C., 'Static Racking Tests on Concrete Masonry Walls', Proc. Int. Conference on Masonry Structural Systems, University of Texas, 1967, pp. 185-191.
Jennings, P.C. (Ed.), 'Engineering Features of the San Fernando Earthquake', California Institute of Tech. Report EERL 71-02, June 1971, 512pp.