Detailing of prestressed concrete piles for ductility
DOI:
https://doi.org/10.5459/bnzsee.17.4.251-271Abstract
The role of spiral reinforcement in improving the ductility of concrete and the background to the New Zealand concrete design code equations for spiral reinforcement in potential plastic hinge zones are outlined. Tests and analysis of eleven full scale pretensioned prestressed concrete piles with a 400 mm octagonal cross section are reported. The tests were to determine the available ductility of the piles when subjected to large inelastic cyclic deformations from lateral loading which simulated severe seismic loading. The main variables of the tests were the amount of longitudinal nonprestressed reinforcement present, the applied axial load level, the amount of transverse spiral reinforcement present and the use of either Grade 275 or hard drawn spiral steel. The results showed that when the code specified quantity of spiral steel was present the piles were capable of undergoing very large post-elastic deformations when subjected to cyclic lateral loading without significant loss in load carrying ability. Piles with about 50% of the code specified quantity of spiral reinforcement were capable of reaching displacement ductility factors of at least ±4 providing the spiral spacing did not exceed about 4 tendon diameters. When the spiral reinforcement was provided by hard drawn wire the pile response was eventually limited by the fracture of the confining steel reinforcement, whereas piles with Grade 275 steel spirals did not suffer confining steel fracture.
References
Sheppard, D.A., "Seismic Design of Prestressed Concrete Piling", Journal of the Prestressed Concrete Institute, Vol. 28, No. 2, March-April 198 3, pp.20-49. DOI: https://doi.org/10.15554/pcij.03011983.20.49
Gerwick, Ben C. Jr., "Seismic Design of Prestressed Concrete Piles", Proceedings of the 9th Congress of the Federation Internationale de la Precontrainte, Volume 2, Stockholm, 1982,pp.60-69.
Park, R. and Paulay, T., "Reinforced Concrete Structures", John Wiley and Sons, New York, 1975, 769p. DOI: https://doi.org/10.1002/9780470172834
New Zealand Standard Code of Practice for the Design of Concrete Structures, NZS 3101, Part 1:1982, Standards Association of New Zealand, Wellington 1982, 127p. (Commentary: NZS 3101, Part 2: 1982, 156pp).
Falconer, T.J. and Park, R., "Ductility of Prestressed Concrete Piles Under Seismic Loading", Research Report 82-6, Department of Civil Engineering, University of Canterbury, February 1982, 121p.
Park, R. and Falconer, T.J., "Ductility of Prestressed Concrete Piles Subjected to Simulated Seismic Loading", Journal of the Prestressed Concrete Institute, Vol. 28, No. 5, September-October 1983, pp.112-144. DOI: https://doi.org/10.15554/pcij.09011983.112.144
Pam Hoat Joen, and Park, R., "Ductility of Prestressed Concrete Piles Subjected to Simulated Seismic Loading", Research Report No. 84-4, Department of Civil Engineering, University of Canterbury, February 1984, 170p.
Mander, J.B., Priestley, M.J.N, and Park, R., "Seismic Design of Bridge Piers", Research Report No. 84-2, Department of Civil Engineering, University of Canterbury, February 1984, 442p plus appendices.
Park, R. and Leslie, P.D., "Curvature Ductility of Circular Reinforced Concrete Columns Confined by the ACI Spiral", 6th Australasian Conference on the Mechanics of Structures and Materials, Vol. 1, Christchurch, August 1977, pp.342-349.
Thompson, K.J. and Park, R., "Ductility of Prestressed and Partially Prestressed Beam Sections", Journal of the Prestressed Concrete Institute, Vol. 25, No. 2, March-April 1980, pp.46-70. DOI: https://doi.org/10.15554/pcij.03011980.46.70
Seismology Committee, "Recommended Lateral Force Requirements and Commentary", Structural Engineers1 Association of California, 1975, 21p. plus appendices.